Thierry Claudien Uhawenimana, Stella M. Umuhoza, Jean Bosco Ndayambaje, Yvonne Delphine Nsaba Uwera · 15 authors
BACKGROUND: Visual impairment is a major global public health concern, disproportionately affecting populations in low- and middle-income countries (LMICs), where access to eye care services remains limited. In 2019, the Rwandan Ministry of Health integrated eye care services into the Performance-Based Financing (PBF) framework to improve accessibility, service quality, and utilization. However, service users' perspectives on this initiative remain underexplored. This study aimed to examine service users' perceptions of accessibility, quality, affordability, satisfaction, and challenges in accessing eye care services at primary healthcare facilities. METHODS: An exploratory qualitative study was conducted in six purposively selected health centers in Rwanda. A total of 72 participants were recruited using maximum variation sampling, including older adults, individuals with disabilities, and participants from different socioeconomic backgrounds. Data were collected through six focus group discussions (FGDs), each comprising 8-12 participants. Discussions explored perceptions of accessibility, quality, affordability, satisfaction, and recommendations for improvement. Audio recordings were transcribed, translated into English, and analyzed inductively using Dedoose software. Trustworthiness was ensured through prolonged engagement, member checking, peer debriefing, and triangulation. RESULTS: Participants reported that the decentralization of eye care services to health centers improved geographical access and reduced travel time. However, financial barriers remained a major constraint, particularly due to the cost of eyeglasses and certain medications not fully covered by Community-Based Health Insurance (CBHI). Users also described inconsistencies in service quality, including frequent stock-outs of essential supplies, limited equipment, and variability in the availability of eye care personnel. Despite these challenges, many participants expressed satisfaction with provider attitudes and interpersonal care, highlighting respectful and supportive interactions with health workers. At the same time, dissatisfaction was reported due to systemic inefficiencies such as limited service days, understaffing, long waiting times, and referral-related burdens. CONCLUSIONS: Findings indicate that decentralization may have contributed to improved geographic accessibility and perceived service responsiveness; however, these improvements are uneven and remain constrained by financial and system-level barriers. Addressing these barriers through expanded service packages, reliable supply chains, human resource strengthening, CBHI coverage, and community education is critical to optimize equitable eye-care delivery.
Ophthalmology is a discipline not merely concerned to the resolution of quantitative visual problems (visual acuity and visual fields), but, on the contrary, great number of patients of an ophthalmological office complain of the bad quality with which the visual tasks are related. âGoodâ vision in each eye, but with discomfort (asthenopia) may be caused by the lack of binocular fusion, be it due to the images of different sizes (aniseikonia, either by inadequate corrections of anisometropias or by different components â axial and refractive â of isometropias), be it due to diplopia and confusion (in heterophorias and convergence insufficiency). Notwithstanding, the most prevalent cause of such asthenopia discomforts is, essentially, monocular (although it may also be binocular), the intolerance to the use of accommodation. It is remarkable that in the history of ophthalmology, the accommodation is one of the newest ocular properties, only explained at relatively short time by Helmholtz,[1] but with its theory till recently disputed,[2,3] it allowed the differentiation between the concepts of hyperopia and presbyopia[4] and was quantified at the different ages by Duane.[5] As a matter of fact, the accommodation is an ocular function used in a practically continued mode. By definition, it should be in rest only if an eye is required to âseeâ objects at infinite distances while keeping the condition of being emmetropic or having hyperopia totally corrected by optical means. Hence, the natural, synchronic, association between accommodation and convergence for near fixations (a synkinetic relationship) led to propositions of formulations for an âobjectiveâ calculation of visual comfort.[6,7] The very laborious methods demanded the knowledge of the oculomotor balance at different positions of gaze, that of the respective binocular fusional capabilities and of the amplitude of accommodation. It is obvious that the evaluations of possible deviations of the visual axes at given distances (heterophorias) and the respective fusional capabilities of compensation are basic propaedeutic elements of the ophthalmological examination. However, in daily practice, such disturbances are of fewer clinical occurrences than those of accommodation and should be treated independently of it by several reasons, among which: (1) The relationship between accommodation and convergence is variable in different people;[8] (2) it is not reciprocal (accommodation evokes convergence â read as âophthalmic lenses change convergenceâ â while convergence almost does not change accommodation â read as âprisms practically do not influence accommodationâ;[9] and (3) although be assumed that the relationship between the stimulus to the accommodation, A (not necessarily its response) which causes a convergential effect (AC, the accommodative convergence) remains relatively constant during a subject's life (the AC/A relationship),[10] the convergence is, at the different ages practically unchangeable, while accommodation progressively decreases. At last, the accommodation performance may be even quantitatively normal for a specific age but â due to the continuity of the exercitation (to compensate for total or residual hyperopia) and/or by the relatively excessive and prolonged efforts to adjust images on the retina of objects at near distances â determine signs (esodeviations, by the accommodative convergence) and symptoms (headache, ocular pain, conjunctival hyperemia, lachrymation, blurring of images, âaversionâ to read and write, eyes rubbing, hordeola, etc. Therefore, as depending on the extension of time by which accommodation is exerted, the knowledge of its total capability (the measurement of its amplitude) is not so relevant than the amount by which its prolonged efforts (though a small part of such total capability) may be tolerated. Actually, for example, although a weightlifter may succeed to lift 1100 lb. by a very short time (a proof of maximal strain, as it is the measurement of the near point of accommodation, with which the amplitude of accommodation is calculated), he does not support to carry about a much smaller weigh all day long. Therefrom emerge the concept of accommodative tolerance.[11] Up to now, there are no rigorously established measurements for the accommodative tolerance, in different age groups. However, they may be estimated by empirical knowledge of approximate medium values for each age group and easily memorized [Table 1]. Variations of small magnitudes around them (e.g. ±1.5D or 2.0D for the 5-year-old group, but decreasing for older age groups) might be aggregated.Table 1: Approximative medium values of the accommodative tolerance (TA) for different age groups and respective estimated variationsAs a matter of fact, one knows that children with âhighâ hyperopia do not compensate them (though they might have, theoretically, higher accommodative capabilities to do so) and develop bilateral amblyopia by the worse quality of retinal images of such no conveniently corrected refractive unbalances. On the other side, it is well accepted that up to the 5 years of age hyperopia of +4D be âsafe,â well tolerated (continuously compensated, with no clinical problems). Therefore, for the 5-year-old children, that value (+4D), as a rule, should be the maximum dioptric value of no corrected (residual) hyperopia to be left, that is, the value of the accommodative tolerance for such an age group. For the 15-year-old group, it is exceptional that hyperopia over +3D (accommodation for ânear distancesâ is about 6D, or more, depending on the distance to the fixation point) be well tolerated. For 25-year-old people, the values of (sub-corrected or no corrected) well-tolerated hyperopia are reduced to about 2D (remember that 5D of accommodation is needed for the conventional near work distance); for the 35 years age group, the accommodative tolerance drops to, approximately, 1D; and at people 45 years old, it becomes null. A hyperope of +0.5D (who requires 3.5D â or more â for near distances) though might have an accommodation of up 6D does not, commonly, support exert it durably for his/her daily tasks. Therefore, one loses 1D of accommodative tolerance each 10 years, or about 0.1D/year, starting from the age of 5 years. This lead to the empirical equation of the accommodative tolerance (TA) as function of an age (y) as:[11] TA = 4,5 â 0,1 y How, then, is measured the accommodative tolerance of a patient, to know if it is, or not, adequate for his/her age? By now it is not measured. Nor, perhaps, such measurement shall one day be necessary, since the subject, or those who answer for the subject âknowâ that value. Therefore, simply ask for such a value, something as âWhat is the consultation reason?â Follow some examples about how to interpret the answer. Suppose three children, all of them with a +4D hyperopia in each eye and normal complementary examinations. Theoretically, the expected normal measurement for their accommodative tolerances should be 4.1D, practically identical to the value of the hyperopia. The âAâ child's parents relate that she started presenting a sporadic, intermittent, convergent strabismus some months ago, which became constant the last week. Till an opposite proof, we face a simple accommodative esotropia, to which the classical recommendation is the neutralization of the cause, a total correction of the hyperopia (+4D). The âBâ child's parents refer that they come to the ophthalmological examination only to know if everything is normal, there are no complaints, or manifestations which worry them. They are answering âOur child has accommodative tolerance for his 4D (minimum) of continued accommodative efforts, maybe more.â Hence, there is no validity to correct what is already naturally corrected, without signs and symptoms. Prescription zero. The âCâ child who presents a whole collection of very typical accommodative asthenopia signs draws forth more alternatives of optical prescriptions. Some would prefer to start by low prescriptions, as +1D. Now, a child who does not tolerate continuously accommodate 4 D for distant fixation and much more for near fixations (7 D or above), very much probably will follow with practically the same manifestations imputable to the use of accommodation, if it is kept in almost identical values (respectively, 3 and 6D). In an eventual return, the one decides to increase the correction to +1.5D with, probably, the same failure, for the mentioned reasons. It should be better to start with a âhighâ prescription, as +3.5D, which would neutralize, practically, almost all accommodative effort to distant fixations and would greatly reduce it for near visual work. Anyway, such a prescription very much probably would âelucidateâ the question, be it by making the signs and symptoms disappear, or by informing â if they were kept â that they are not due to the accommodative efforts (residual hyperopia of +0.5D in a child is too low as a possible cause). Obviously, would come the question: âBut the prescription could not be +3D?â to which the right answer is âI do not know. Let us ask the subject, or his/her family next timeâ.(It is expected that contented clients come back.). So, when the subject comes back, this value (+3D) is prescribed. Then, two things may happen: The return of symptoms and signs, though attenuated (conclusion: âWe have hit the bulls-eye with the first prescription, so that +3.5D is the accommodative tolerance of such a childâ) or the child remains healed (and the family happy, because âThe Doctor is decreasing the eyeglasses powerâ). Now, what about +2.5D? We do not know. Let us check next time, always with two alternatives: That by which the âcorrectedâ value of the accommodative tolerance for the child is found (then, +3D), or that with which the child follows without signs and symptoms and the family is grateful because the optical prescription is still lower (with the possibility it might be still reducedâŠ). Consider a young man, 20 years old, hyperopia +2.0D in each eye. The expected accommodative tolerance for his age is 2.5D which, theoretically, should be enough for the continued compensation of the hyperopia, but not, necessarily, for greater and persistent use of accommodation. Let us ask the young man. And he answers that he feels headache and visual blurring after some hours of using the personal computer (at 40 cm, i.e. +2.5D, which corresponds to 4.5D of prolonged accommodative efforts), but no complaints when the accommodation for near work is scarcely required (that is, he keeps an accommodation of 2.0D, or eventually little more, but not more and persistently). He is, clearly saying: âAlthough my accommodative tolerance be sufficient to keep me without continued correction of my hyperopia (2D of accommodation) I do not tolerate the sustained use of 4.5D of accommodation. I need eyeglasses for close proximityâ. If he had, also, complains for far visual attention, the prescription +1.5D for constant use (leaving an accommodation of only 0.5D for fixation to far objects and 3.0D for close work) should be convenient. However, by the young man report, perhaps, the prescription of +1.5D uniquely for the personal computer (at 25 cm) use be convenient, but the suggestion that he may use it also in a cine; or still a little more, eventually +2.0D (but then, only for near distances), and always based on the magnitude and subtleties of the informed complains. The benefits of using the accommodative tolerance concept for optical prescriptions imply the knowledge of the ocular refraction measurement with the accommodation totally relaxed, a condition which, by the way, corresponds to the proper definition of the balance state of the optical ocular system. However, as the accommodation is evoked by the command of an autonomic nervous system, the guarantee of such a complete relaxation is only given by cycloplegia. At last, optical prescriptions (mainly those of hyperopia) necessarily require two knowledges: That of the âstaticâ ocular refractometry (which is a kind of pleonastic construction, since there is no possible assurance of this measurement, if the accommodation is active, or âexcessiveâ, or spastic); and that of the accommodative tolerance (related to the subject's age and complains). Fortunately, however, those two only information, saving time of (other) examinations, are sufficient for almost the totality of good optical prescriptions.
We are pleased to respond to Gellerman and Bernstein's (G&B) critique of our review. Unlike many fields, science is self-corrective and largely succeeds because of its openness to criticism. We applaud G&B's efforts to develop a useful device for the important purpose of measuring macular pigment (MP) noninvasively. We were disappointed, however, that G&B feel that we have an âunyielding bias against the use of Raman spectroscopy to quantify MP in vivoâ We would criticize any method that made claims regarding these important issues that were not supported by reasonable evidence. In our review, we critically analyzed both psychophysical and physical methods and noted shortcomings and strengths. We pointed out that âas currently conceived,â the Raman method of MP optical density measurement is invalid. In a recent review,1 however, we provide many suggestions for how the method could be improved. An acceptable response to our criticisms would be to restrict counterclaims to those supported by reasonable evidence or, even better, to actually test the critical assumptions. For example, one could measure lens density and diffusion at 488 and 527 nm, pupil size, head movements, and so on, on a sample of varying age and quantify the effects of these variables on the Raman signal. If these factors really do have minimal influence as G&B continue to assert, our questions, which are legitimate despite their protestations, could be easily addressed. Providing solid evidence and/or reasoned arguments is undoubtedly a better scientific practice than simply responding negatively and, personally, to being critiqued. Readers can, after all, evaluate the arguments and evidence and come to their own conclusions. What we hope is obvious to all readers is that personal motivations, even if they do exist, are completely irrelevant. For example, G&B suggest that our critique of their method is biased because of a commercial interest by one of the authors. They also describe our review as a âstring of shortcomings, misrepresentations, and flawed conclusions.â Such charges do not address content; they simply seek to discredit the source. G&B also suggest that our critique simply duplicated our earlier published correspondence on these issues. It is, however, legitimate to raise similar issues in different papers (G&B, however, often duplicate text and graphs verbatim, which is not an accepted practice). When there was sufficient overlap, we simply referenced earlier sources. Our primary goal with the Raman section of our review was to quantify the confounds that we had identified in earlier papers. G&B also note that our review fails to include any of their rebuttals to our arguments. However, we were careful to note that there is debate regarding these issues and refer the readers to the relevant literature. Most of our criticism of the Raman method is organized around addressing the points that G&B have made in their many publications using the Raman device (often quoting the points G&B made directly). It is, of course, proper scientific practice to cite debate when discussing an issue for which significant debate exists. This is a practice G&B do not follow, e.g., see the most recent papers by Bernstein et al., Ermakov et al., and Ermakov et al.2-4 We have been motivated to write about the Raman method because of the importance of this area and the dramatic claims made by G&B. For example, recently Ermakov et al.3 wrote âThe ease and rapidity of Raman MP measurements, the simplicity of the instrumentation, the high accuracy of the measurements, and the lack of significant systematic errors should make this technology attractive for widespread clinical research.â As long as G&B continue to assert validity claims in the absence of evidence, they should expect âincessantâ criticism of such claims to continue. This is simply a manifestation of the rigor of our discipline. The validity of a method has nothing to do with its assumed subjectivity or objectivity. One could, for example, argue that the Raman method has an important subjective component because it relies on a subject's own perception of whether they are, or are not, properly aligned. According to Vogt,5 subjective methods are based on the feelings and intuitions of the researcher. Objective methods, in contrast, are based on the âobject,â i.e., they are independent of the feelings, beliefs, or desires of the researcher or subject. Based on this definition, all methods currently used to measure MP are objective. Referring to psychophysical methods as subjective seems to reflect a general bias based on the idea that if a test requires a subject's response, it is inherently less accurate despite means for controlling bias, validating the response, and so on. A similar general bias appears to apply in the opposite direction. To some, direct physical methods appear inherently more accurate and less subject to bias despite free parameters, questionable assumptions, a lack of validity testing, and so on. Such biases have no bearing on the actual validity of a method. Validity has to be determined based on a specifiable and reasonable criterion. G&B take some issue with our criterion: matching spectral absorbance profiles with ex vivo curves. This, however, is a common criterion for determining the identity of a signal (i.e., if the spectral curves match, one can be confident that they are measuring carotenoids). George Wald, for instance, originally used this method to identify MP as composed of xanthophylls.6 G&B are, of course, correct in noting that one cannot determine wholly from spectral curves whether they have correctly measured absolute quantity. Essentially, G&B argue that the HFP method yields values that cannot be directly evaluated against known standards and is, therefore, not validated (This argument is, of course, the very one that we have made about the Raman method and has not been refuted by G&B.). When applied to HFP, however, the argument is specious. HFP relies on a derivation strategy rather than a calibration-against-a-standard procedure as is possible in bench scenarios. This derivation is based on a double normalization procedure using wavelength (i.e., relative sensitivity at two wavelengths, those absorbed by MP, e.g., 460 nm, and a reference wavelength that is not, e.g., 560 nm) and retinal site comparisons (two sites, one where MP is present, e.g., the foveal center, and one where MP is known to be optically undetectable, e.g., 7° off the fovea). These normalization procedures are based on the well-established extinction spectrum of MP and the near identity (when using appropriate stimulus conditions) of the relative spectral sensitivity of the response mechanisms at the retinal sites of comparison. The rationale for these assumptions is based on an extensive and well-established literature that is covered in our review. G&B are incorrect in their notion that HFP would be nonlinear as a result of saturation effects. In fact, the inherent perfect linearity of HFP as a measure of MP is an important strength of the method. This is because HFP relies on quantal absorption in outer segments, which are, of course, located behind the MP. Thus, the MP is treated as a filter that merely attenuates the light reaching the receptors. The receptors merely act like photocells responding to quanta. Furthermore, HFP uses a criterion response rather than response amplitude. In other words, the null flicker response is achieved whenever the quantal rate of the variable short-wave component results in a magnitude of response equal to that of the fixed midwave standard. Thus, independent of the amount of MP, the response that determines the match point is of fixed amplitude. The subject merely adjusts the amount of short-wave light until the null point is achieved. A departure from nonlinearity at high OD levels would only result from such extreme light levels as to cause anatomic damage to the eye, an absurdity because such light levels would correspond to an MP OD many orders of magnitude above observed values. As we note within our review, linearity is, of course, a central issue. In comparison even to other physical methods, the Raman method fares particularly poorly in this respect because the signal is returned directly from the molecules of MP. Thus, the deeper layers are screened by the shallower layers. For lower OD levels (approximately <0.30),1 the response could be considered acceptably linear. This range of acceptable linearity could, theoretically, be increased by increasing the intensity of the stimulating laser, but then safety issues would become a serious concern. Using current intensity levels, the response is increasingly nonlinear past 0.30 and this problem cannot be corrected, adjusted, or calibrated away. It is fair to question whether a method designed to measure MP levels returns accurate quantitative estimates for individual subjects. In our review, we discuss this issue with respect to all of the in vivo methods. The Raman method fails seriously even at low levels where the method might be considered acceptably linear. For example, imagine an individual has a true MP OD of 0.30. The Raman signal could be as high as 1500 if none of the signal is lost, or the signal could be near zero if lens absorbance is as high as 0.30 at 488 and 527 nm and scatter is large (such individuals have been identified in the empiric literature, especially at older ages). This permits a range of error that makes interpretation of RCs (Raman count) impossible even on an ordinal scale. In this example, a subject could appear to have either zero MP or average MP density with no way of knowing the true values. G&B note that we did not cite Savage et al.7 and Zagers et al.8 and conclude that âif these more recent results had been used for their calculations, their putative reduction factors would have been much lower in magnitude.â We estimated that the amount of reduction in the Raman signal resulting from lens absorbance between the ages of approximately 20 and 60 was 41%. As we note in our review (footnote h), this estimate is quite similar to that made by G&B,9 which was 38% between the ages of 20 and 60 years. If our âputative reduction factor would have been much lower in magnitude,â it would then be much lower than the estimate made by G&B themselves. Lens absorbance could be easily corrected for if it was simply the average error introduced by the lens that was important. Unfortunately, to interpret individual RCs, knowing the amount of attenuation resulting from absorption by an individual lens is critical. Despite their own estimate of a systematic age-related error of 38%, Ermakov et al.3 wrote that there were no âsignificant systematic errorsâ with the method. In another recent paper, Ermakov et al.4 wrote that âTo our knowledge there are no serious confounding factors for the technologyâ These assertions directly contradict G&B's own analysis and conclusions (and inspire our âincessant lettersâ). The Zagers et al.8 paper was not available when we wrote our review, which was submitted in March 2003. We have since discussed the Zagers et al. and Savage et al. papers in a more recent review1 pointing out that all of the ex vivo data and all of the other in vivo data also support the idea that lens OD at the Raman wavelengths of 488 and 527 nm is significant, increases with age, and is quite variable across subjects at all ages. The fact that two papers conclude that lens absorbance is not as high at the Raman wavelengths as all other papers (>20 other papers using both ex vivo and in vivo methods) find is missing the point. Unless the majority of empiric papers on this topic are incorrect and the lens is perfectly transparent at the relevant wavelengths for all subjects irrespective of age, it will represent an unknown source of error. Although G&B persist in simply claiming that this error is insignificant, that determination cannot be made in the absence of evidence. This is not a âmisleading, pejorative statementâ that reflects an âunyielding bias.â Based on the author's own conclusions, this is a legitimate question. In fact, confounding by lens absorption alone would invalidate their method, e.g., it could introduce approximately 30% to 40% error of unknown direction. The comparison of HFP and Raman results, cited in the review by Bernstein et al.,2 would have been difficult to evaluate (even if their paper would have been available when writing our review) because virtually no details were provided regarding the comparison. In a more recent review,1 we do discuss the available data regarding the comparison between HFP and the Raman method. The only study that has been published as a full manuscript (including full detail regarding the methods and procedures) is Neelam et al.10 Neelam et al. found that the relation between HFP and RCs was described by an r2 of approximately 0.10. The fact that the methods are measuring the same variable in the same individuals at the same time and only explain approximately 10% of the variance is not a strong argument that the methods agree (particularly if one tried to expand the sample to include the elderly). True agreement would also have to be reflected in the ability to translate the scores such that the relation could be described with an intercept near zero and a slope close to one. It is worth noting also that G&B continue to tout the significance of the correlation between HFP and Raman as evidence for the validity of their method because they argue that HFP is not particularly reliable and may not be valid (see their points 1 and 8). For example, Ermakov et al.3 recently wrote âAs a precaution, we avoid media-opacity-related problems by limiting the measurements to subjects with visual acuity better than 20/80. A correlation of our MP Raman responses with data derived by high-performance liquid chromatography and flicker techniques is proof that these precautions are adequate.â We assumed that the authors evaluated the validity of the HFP technique before citing it as evidence. With respect to the former statement, excluding subjects based on visual acuity will not reduce confounds based on individual differences in the lens density of normal subjects because the two have not been shown to be related. It is certainly true, however, that many of the physical methods have shown much more pronounced deflections than is generally seen in the HFP data. How these types of deflections reflect the underlying biology of the retina is an interesting question. It is therefore important to confirm that these topographic irregularities are real. In some cases, for instance, they may reflect artifacts with the method. For example, G&B, when using the Raman method in the imaging mode, report on an individual that they observe had a âcentral hole in the MP distribution.â Based on what is known regarding the underlying anatomy, it is hard to imagine an actual hole in the center of the MP distribution of a normal healthy individual. Unusual results require careful scrutiny. As we note in a recent review,1 the inherent nonlinearity of the Raman signal could create distortions when used to map MP spatial profiles (as a result of different proportions of the pigment being measured based on location). For example, Hammond et al.13 provide MP spatial density data for a subject whose central MP peak was 1.63 OD (based on an extrapolation from the measured point of 1.35 at a radius of 6 minutes) but whose MP density at 3° was 0.30. Using the Raman calibration curves, the central peak for such a subject would be underestimated by 53%, whereas the 3° site would not be underestimated. In this instance, artifacts with the method would create distortions in the profile that did not, in truth, exist. All areas of science tend to share a focus on methodology. We agree with G&B that the pursuit of multiple methods of measuring MP in vivo is extremely beneficial, including resonance Raman spectroscopy. G&B have claimed that our review of their methodology is biased as a result of the commercial interest of one of the coauthors. One of the coauthors, Dr. Wooten, has built a relatively small number of HFP-based macular densitometers for fellow researchers and colleagues. Our review, however, was in no way designed to promote this instrument nor was the instrument even mentioned. We do not hold a patent or claim ownership of the HFP technique, in specific, or obviously psychophysics, in general. Many laboratories have used HFP to measure MP and results have been published using the method before our laboratory (e.g., Bone).16 Ultimately, critical evaluation must stand on its own merit, irrespective of the author, and is a central feature of our field and an obligation of all scientists. If researchers in the area of macular pigment do not critique their own work, then who will? Billy Wooten, a coauthor of this letter and the original article, is a principal in Macular Metrics Corp. (Providence, RI), which manufactures densitometers. These densitometers use heterochromatic flicker photometry and are used to measure MP. Billy R. Hammond, Jr Vision Science Laboratory University of Georgia Athens, Georgia Billy R. Wooten Bill Smollon Walter S. Hunter Laboratory Brown University Providence, Rhode Island